Service and Parts Manual
10
The objective of this section is to assist the
service technician in diagnosing problems that
are related to installation and/or leveling.
It is extremely important that the unit is level.
If it is not level, the ice mold will not fill evenly.
This can cause a reduction in ice rate, uneven
sized cubes or water spilling into the storage
area which will cause the ice in the bin to melt
prematurely. See Figure A.
Remember that floors near drains have a ten-
dency to slope towards the drain.
Leveling the Unit
1. Use a level to check the levelness of the icemaker from
front to back and from side to side. See Figure B.
2. If the icemaker is not level, adjust the feet on the cor-
ners of the unit as necessary. See Figure C.
3. Check the
levelness
after each
adjustment
and repeat
the previ-
ous steps
as neces-
sary until
the unit is
level.
Installation Requirements
• The unit may be built into a cabinet. There is no minimum clearance requirement for
the top, left or right sides of the unit.
• The location must allow enough clearance for water, drain, and electrical connections
in the rear of the unit.
• The location must not obstruct air flow to the front of the unit.