U-Line SS1095 Installationsanleitung Seite 5

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 4
09/2008 5 www.U-LineService.com
SS1095
MARINE SERIES
Model SS1095FD: Follow the cut-out drawing in (Figure
3). The unit must sit in a frame structure with a frame
thick enough to accommodate mounting the flange to its
sides and top, and a base high enough to align the door
with other cabinet doors. Make the frame width 14-5/8”
and the height 24-3/4”. This will allow for ease in
installation and removal of the unit for servicing. 18-3/8”
depth includes the door and water line connection.
Note: If you purchase a U-Line WATERHOOKUP kit, the
minimum depth required to install the unit is 17-5/8”. The
recommended receptacle location is an adjacent cabinet.
If receptacle will be behind unit, additional space is
required.
Cut-Out
Height
24-3/4"
16-1/8"
Minimum Opening
18-3/8" Minimum
See Electrical
Specifications
for Power Supply
8" Height
From Floor
Filler Panel (Not Provided by U-Line) –
Needed to Attach Mounting Flange on Unit
Toe Kick
14-5/8"
Cut-Out Width
3/4"
Minimum Flange
Mounting Area
Figure 3
Seitenansicht 4
1 2 3 4 5 6 7 8 9 10 ... 15 16